2.8KVA Tradie Generator

TOUGH. POWERFUL. READY.

PROMAC 2.8KVA Tradie Generator

  • HP6.5
  • From 68 dB(A) @ 7m
  • Recoil starting system
  • Max Watts 2300W
  • Rated Watts 2000W
  • Weight 45KG
  • Fuel tank capacity 18L
  • Run time 15 hours @ 50% load
  • Dimensions L59 x W43 x H48cm
  • IP66 rated RCD and weatherproof outlets
  • 1 Power outlet – 15amp
  • Wheel and Handle kit included
  • High quality clean power
  • Sine wave alternators
  • Automatic voltage regulators
  • 12 volt outlet
  • 3 year warranty on Torini Engine (4 year domestic)

 

    PROMAC Tradie Generators are loaded with IP66 Rated power outlets, RCD (Residual Current Circuit Breaker), Rollover frames and Heavy duty wheel kits. PROMAC Tradie Generators have a high quality AVR (Automatic Voltage Regulator) with digital stability control program. They also feature Hi-Lo limit electronic safety shut off making Promac generators one of the safest on the market.

    All tradie units have an advanced alternator and electronic technology, this allows our generators to produce a VERY PURE, CLEAN energy supply. Thanks to these advanced technologies our generators are able to power the most sensitive electronic equipment such as: mobile phones, laptops and other micro-processor appliances.

    Boasting a 3 year warranty for our Torini Engine merged with an innovative design and easy to operate unit, makes our generators one of the toughest and most reliable units on the market today.

    < 5% THD (Total Harmonic Distortion)

    Part NumberDescription RRP 
    GT028Promac Tradie Generator- 2.8KVA, Torini Engine HP6.5 $         1000.00

    Choosing the Right Generator for you!

     

    COMMON FORMULAS:

    • 1KW =             1000W
    • 1KVA =             800W
    • 1HP =             750W
    • 1KVA =             4Amps (Single phase)
    • Watts =             Volts x Amps
    • Amps =             Watts/Volts

    General Rule #1

    Compressors and other induction motors (e.g. Fridges, freezers and air conditioners) will require a minimum of 3 times the HP of the motor to the KVA to start. For example, an air conditioner with 1HP motor will require 3KVA every time that motor cycles in.

    General Rule #2

    Common Applications – Welders & Compressors:

    • 120amp welder or 8CFM compressor requires a minimum of 5KVA
    • 140amp welder or 10CFM compressor requires a minimum of 6KVA
    • 160amp welder or 12CFM compressor requires a minimum of 7KVA
    • 180amp welder or 14CFM compressor requires a minimum 8KVA

    General Rule #3

    To work out the generator size required, simply add the wattage of all appliances or construction tools likely to be used at the same time. Don’t forget to allow for any induction motors. Use the Common formulas above to calculate your minimum KVA required.

     

    Brochure

    PROMAC Generator Brochure